You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
Repository navigation
Commit 44ea3b5
Browse filesBrowse the repository at this point in the historyBrowse files
Anton Vynohradov
committed
Update Doppelstep to v0.3.0 and Stepper-C to v1.5.0
Doppelstep (projects.js, robot.html):
- Status "v0.3.0 · Pre-release" instead of "In progress"
- 157 tests per CI run (was 91)
- Drives a real 17HS19-2004S1 stepper at 12 V and 24 V, checked
with DYNAMIXEL Wizard 2.0; hardware comparators (0.5 µs),
self-test and overheating trip
- Done / Next lists follow the project status in the README
Stepper-C (projects.js, index.html):
- v1.5.0 (was v1.2.0)
- 512 B RAM per motor, 240 B worst-case stack
- Dead-time compensation, power-stage self-test, port to the
B-G431B-ESC1; stall reported 48 ms after the pull-out angle
Regenerate the prerendered cards in projects.html and articles.html.
Signed-off-by: Anton Vynohradov <avynohradov@systemfromscratch.com>
Copy file name to clipboardExpand all lines: website/assets/js/projects.js
+13-11Lines changed: 13 additions & 11 deletions
Original file line number
Diff line number
Diff line change
@@ -136,19 +136,20 @@ window.SFS_PROJECTS = [
136
136
"Hardware-agnostic closed-loop microstepping current control for two-phase stepper motors in C11, with sensorless stall detection: from a position command to phase voltages, with the hardware reached only through callbacks.",
137
137
features: [
138
138
"Per-phase PI current control tuned from R, L and one bandwidth; back-EMF feed-forward, anti-windup, bus voltage compensation",
139
-
"Sensorless stall detection: a back-EMF observer reports a stalled rotor or lost synchronism, 43 to 60 ms after the load angle passes 90° on the motor model",
139
+
"Dead-time compensation from the measured bus voltage and the current reference: on the motor model the largest current error of a 1 Hz move drops from 16 mA to 3 mA",
140
+
"Sensorless stall detection: a back-EMF observer reports a stalled rotor or lost synchronism, 48 ms after the rotor passes the pull-out angle on the motor model",
140
141
"1–256 microsteps, trapezoidal motion planning, homing and exact integer positions; fixed-point or float backend",
141
-
"Two H-bridges or three half-bridges; overcurrent, over/undervoltage and fault protection",
142
-
"100 % line and branch coverage in both backends, 0 MISRA C:2012 violations; run in the loop against a motor model in Stepper-Lab",
142
+
"Two H-bridges or three half-bridges; self-test of the power stage and the wiring before the first enable; overcurrent, over/undervoltage and fault protection",
143
+
"Ported to the B-G431B-ESC1 with a 17HS19-2004S1 motor; 100 % line and branch coverage in both backends, 0 MISRA C:2012 violations",
"Zephyr RTOS firmware that turns a two-phase stepper motor and a small STM32 motor-control board into a DYNAMIXEL XM430-W350 smart servo: ROS 2, DynamixelSDK and DYNAMIXEL Wizard control it without changes.",
221
222
features: [
222
-
"Full XM430-W350 (model 1020) Control Table over Protocol 2.0; ros2_control loop at 100 Hz tested with the official DynamixelSDK",
223
-
"Closed-loop microstepping current control in a 20 kHz interrupt; overcurrent, bus voltage and shared-leg faults switch the outputs off inside it",
224
-
"Simulated motor and power stage on the board or on a PC (native_sim), so motion and protocol work before a motor is connected",
223
+
"Full XM430-W350 (model 1020) Control Table over Protocol 2.0; checked with DYNAMIXEL Wizard 2.0, and a ros2_control loop at 100 Hz tested with the official DynamixelSDK",
224
+
"Drives a real 17HS19-2004S1 stepper on the B-G431B-ESC1 at 12 V and 24 V: all 20 bench test scenarios, the hardware comparators and two minutes of moves at 1.5 A",
225
+
"Closed-loop microstepping current control (Stepper-C) in a 20 kHz interrupt; comparators switch the gates off within 0.5 µs, a self-test checks the bridge and the wiring before the first Torque Enable, plus an overheating trip",
226
+
"Simulated motor and power stage on the board or on a PC (native_sim), so motion and protocol are tested on every change before they reach the hardware",
225
227
"MCUboot checks an RSA-2048 signature at every start and accepts new firmware over the DYNAMIXEL bus",
0 commit comments