A minimal, copy-paste-friendly example showing how to implement the BACnet B-SS (Smart Sensor) device profile in C# / .NET, using the CAS BACnet Stack. It listens on BACnet/IP (UDP 47808), answers ReadProperty, and is discoverable via Who-Is / I-Am. Its readings follow a sensor Simulation (labelled below), and it reports a broken sensor the BACnet way.
This is a faithful C# port of the reworked BACnetProfileExample-B-SS-CPP (v1.3.0): the same Device, objects, properties, Simulation, Failure Modes, test-only hook and command-line options, proven by the same Wire Tests, which cannot tell the two apart on the wire.
This is the first C# example in the BACnet profile example series. There
is no prior C# example repo to copy structurally - this one was built from the
C++ edition's device model and the Node edition's documentation skeleton, with
a binding mechanism new to the series: native P/Invoke against the
stack's own generated C# adapter, compiled in place from the submodule
(submodules/cas-bacnet-stack/adapters/csharp/), not an embedded C++ link or a
Node N-API addon.
- TUTORIAL.md - how to extend this example and how to review it for conformance. Read it when you start turning this into your own device.
- docs/PICS.md - the Protocol Implementation Conformance Statement: every object, every property, and who answers it.
Versions: this document describes example v1.1.0, built and verified against CAS BACnet Stack 6.0.23 (
6.x@64b2cfac5, loaded as theReleaseDllnative library through the stack's ownadapters/csharp/), at Protocol_Revision 30, with the vendored C#common/helper at v1.1.0 andwiretest/at 0.7.0. Running the example prints all three versions - if what it prints disagrees with this line, trust the program and checkCHANGELOG.md.
B-SS (BACnet Smart Sensor), defined in Annex L of ANSI/ASHRAE 135, is the simplest BACnet device profile - the standard describes it as "a simple sensing device with very limited resources." It is meant for inexpensive, fixed-function sensors (temperature, humidity, occupancy, a contact, ...) that mostly just need to report what they measure when asked.
A B-SS device answers ReadProperty and is discoverable. It does not have to support WriteProperty (a smart sensor is read-only), alarming / event reporting, scheduling, or trending, and this example implements none of them on purpose.
But it is still a full BACnet device. Even the simplest profile must present the standard object model - a Device object, a Network Port object (every device needs one), and its sensor objects - and each object must expose all of its required properties. The CAS BACnet Stack generates most of those automatically (Object_Identifier, Object_Type, Status_Flags, Object_List, Protocol_*, ...); this example supplies the handful that are application-specific. The result is conformant for Protocol_Revision 30. docs/PICS.md lists every property and who answers it.
Device 389001 "Chipkin Example B-SS" (Vendor 389 - Chipkin Automation Systems)
β
βββ Analog Input 1 "Bronze" Present_Value 21.5 -> ramps 18.0 .. 26.0 (REAL, degrees Celsius)
βββ Binary Input 1 "Emerald" Present_Value toggles every 3 s (0 = inactive / 1 = active)
βββ Multi-State Input 1 "Hot Pink" Present_Value 1 -> 2 -> 3 every 4 s (state, 1..3)
βββ Network Port 1 "Vermilion" the BACnet/IP port (required on every device)
What a B-SS is for, in one sentence, from Annex L.4.5 of ANSI/ASHRAE 135-2024:
"Ability to provide values for any of its BACnet objects upon request." A
controller or workstation (the Peer - any BACnet client, or the Python
client in tests/) reads the sensor and gets what it is
measuring now:
- The Peer finds the sensor with Who-Is and reads its
Object_List. - It reads Analog Input 1
Present_Value- say22.0- and again a few seconds later -23.5. The reading follows the (simulated) room temperature, 0.5 C a second. Binary Input 1 and Multi-State Input 1 change too. - Failure Mode - a broken sensor. When the sensor wire breaks, Analog
Input 1
Reliabilityreadsopen-loop(4) and the FAULT bit ofStatus_Flagsis TRUE (clause 12.2.7 derives FAULT from Reliability). The reading stops changing. Repair the wire andReliabilityreturns tono-fault-detected, FAULT clears, and the reading moves again. - Failure Mode - a request it cannot serve. Reading an object or property
the sensor does not have, or an array element past the end, gets the error
clause 15.5.1.3.1 names (
unknown-object,unknown-property,invalid-array-index); a WriteProperty gets a Rejectunrecognized-service, because a B-SS is read-only.
A real smart sensor samples a thermistor, a contact and a selector switch. This
example has none of them, so it simulates them - non-BACnet scaffolding,
outside the BACnet Surface, in section 2 of Program.cs
(SensorSimulationTick(), called beside BACnetStack_Tick()). Once a second:
- the temperature (Analog Input 1) moves 0.5 C, ramping up to 26.0 and back down to 18.0;
- the contact (Binary Input 1) toggles every 3 s;
- the selector (Multi-State Input 1) steps 1 -> 2 -> 3 -> 1 every 4 s.
The broken wire is a test-only hook, not a feature: if the environment
variable CAS_EXAMPLE_TEST_SENSOR_FAULT_FILE names a file, the wire counts as
broken for as long as that file exists. The Wire Tests create and delete it.
Nothing on the network can break the sensor.
To port the example to hardware, replace SensorSimulationTick() with your own
sampling (on a timer or another thread - never block the BACnet callbacks on
slow I/O), and set Reliability from your hardware's own diagnostics.
The example implements exactly the capabilities below - and nothing more, which is the point of a profile example.
| BIBB | Description | Supported |
|---|---|---|
| DS-RP-B | Data Sharing - ReadProperty - B | β |
| DM-DDB-B | Device Management - Dynamic Device Binding - B | β |
| DM-DOB-B | Device Management - Dynamic Object Binding - B | β |
| Service | Notes |
|---|---|
| ReadProperty | Responds to property reads (DS-RP-B). |
| Who-Is / I-Am | Answers Who-Is with I-Am, and broadcasts an I-Am on start-up (DM-DDB-B). |
| Who-Has / I-Have | Answers Who-Has with I-Have (DM-DOB-B). |
| Object type | Instance | Name |
|---|---|---|
| Device | 389001 | Chipkin Example B-SS |
| Analog Input | 1 | Bronze |
| Binary Input | 1 | Emerald |
| Multi-state Input | 1 | Hot Pink |
| Network Port | 1 | Vermilion |
Every required property of every object, and who answers it, is in docs/PICS.md.
This example builds against the CAS BACnet Stack, which is a commercial
Chipkin product - it is not free or open source, and there is no
public/trial build. The stack is referenced here as the private git
submodule submodules/cas-bacnet-stack (tracking the 6.x branch). Unlike
the Node edition (npm workspace, compiles a native addon) or the C++ edition
(compiles the stack's own source straight into the executable), the C#
edition links against a separately built native shared library
(CASBACnetStack_x64_Release.dll on Windows / libCASBACnetStack_x64_Release.so
on Linux) through P/Invoke - see
Build the native CAS BACnet Stack library
below. To get the CAS BACnet Stack (and access to build this example),
contact Chipkin: https://store.chipkin.com/services/stacks/bacnet-stack or
sales@chipkin.com.
This is a self-contained project. It ships:
Program.cs- the example device (section 2 is the sensor Simulation).common/- the shared C# helper (UDP, callbacks, CLI, keys) vendored in.tests/- the Wire Tests (tests/README.md), copied from the C++ edition;wiretest/- the series' shared Wiretest Harness 0.7.0, vendored verbatim.BACnetProfileExampleBSSCS.csproj- the .NET build (net8.0), the same on Windows and Linux.docs/PICS.md- the conformance statement.docs/objects.json- the input to the objects-and-properties generator.submodules/cas-bacnet-stack/- the CAS BACnet Stack as a git submodule (private; requires a license - see above). Itsadapters/csharp/is included directly into this project (<Compile Include>in the .csproj, no NuGet package); itssource/and MSVC/CMake build produce the separate native shared library this example loads at run time.
- .NET 8 SDK or later (verified with SDK 8.0.426 building
net8.0) and the .NET 8 runtime. - Python 3 (standard library only) to run the Wire Tests.
- Git (to fetch the stack submodule).
- To build the native library (see below): on Windows, Visual Studio 2022
Build Tools (MSBuild) building the stack's
projects/msvs/CASBACnetStack/CASBACnetStack.vcxproj; on Linux, a C++17 toolchain (g++/clang++).
git clone --recursive https://github.com/chipkin/BACnetProfileExample-B-SS-CS.git
cd BACnetProfileExample-B-SS-CS
dotnet build -c ReleaseAlready cloned without --recursive? Run git submodule update --init --recursive
first - the build needs the stack submodule's adapters/csharp/ sources.
dotnet build compiles this example and the stack's C# adapter (in place, from
the submodule's adapters/csharp/) - it does
not build the native CAS BACnet Stack library the adapter calls into via
P/Invoke. That is a separate step (below), because it is a native C++ build,
not a .NET one.
The C# adapter's P/Invoke declarations resolve
CASBACnetStack_x64_Release.dll (Windows) / libCASBACnetStack_x64_Release.so
(Linux) from the process's own directory (or the system library search path)
at run time - there is no bundled copy and no NuGet package. Build it yourself
from the stack submodule: it lands in submodules/cas-bacnet-stack/bin/, and
dotnet build copies it from there into this project's build output.
The stack library is never committed to this repository and never released.
The CAS BACnet Stack is a separately licensed product, so the DLL / .so is not
in git (.gitignore covers every library name) and not in any GitHub Release
asset. The only copy of the library outside the submodule is the one the
.csproj puts in the gitignored build output (bin/Release/net8.0/); dotnet publish never copies it.
Each GitHub Release has:
BACnetProfileExampleBSSCS-windows-x64.zipandBACnetProfileExampleBSSCS-linux-x64.zip- the app, published self-contained as one file (BACnetProfileExampleBSSCS.exe/BACnetProfileExampleBSSCS, plus its.pdb; no .NET install needed), withREADME.mdandLICENSE;README.md,LICENSEandmetrics-windows.json/metrics-linux.json.
It does not contain the CAS BACnet Stack library
(CASBACnetStack_x64_Release.dll on Windows, libCASBACnetStack_x64_Release.so
on Linux), because that library is a commercially licensed (paid) product from
Chipkin. The released app cannot run without it. Before anything else, it
looks for the library in the folder that holds the executable; if it is not
there, it prints this to stderr and exits with code 1 (--help and
--version still work):
ERROR: This example cannot run without the CAS BACnet Stack library.
Missing file: CASBACnetStack_x64_Release.dll
Looked in: C:\path\to\BACnetProfileExampleBSSCS\
The CAS BACnet Stack is a commercially licensed (paid) library from Chipkin.
It is not included in this release, so the example cannot start without it.
- To license the CAS BACnet Stack: https://store.chipkin.com/contact-us
- Licensed customers: build the library from the cas-bacnet-stack submodule
(see README.md) and place CASBACnetStack_x64_Release.dll next to this executable.
To run a release: license the stack from Chipkin
(https://store.chipkin.com/contact-us), build the library from the
submodule as below, and put it next to the executable - in the same folder
as BACnetProfileExampleBSSCS.exe / BACnetProfileExampleBSSCS.
Windows - the stack's MSVC project has a ReleaseDll|x64 configuration
that builds exactly this DLL, under exactly this name (a customer-interface
build: no test-tool exports):
& "C:\Program Files\Microsoft Visual Studio\18\Community\MSBuild\Current\Bin\MSBuild.exe" `
submodules\cas-bacnet-stack\projects\msvs\CASBACnetStack\CASBACnetStack.vcxproj `
/p:Configuration=ReleaseDll /p:Platform=x64
dotnet build -c Release # copies submodules\cas-bacnet-stack\bin\CASBACnetStack_x64_Release.dll next to the .exeThe .csproj copies the DLL (or libCASBACnetStack_x64_Release.so) from the
submodule's bin/ into the build output whenever it exists there, so build the
native library first and dotnet build second.
(Adjust the MSBuild path to your Visual Studio / Build Tools install; vswhere
or the "Developer Command Prompt for VS 2022" both resolve it for you if you
have Visual Studio Installer set up.)
Linux - the stack does not currently ship a ready-made shared-library
CMake target (its CMake adapters/cpp/ builds a static adapter; its Linux
projects/linux/ build is for the gtest suite). Build one directly from the
stack's own sources with g++:
mkdir -p submodules/cas-bacnet-stack/bin
g++ -shared -fPIC -std=c++17 -O2 \
-I submodules/cas-bacnet-stack/source \
submodules/cas-bacnet-stack/source/*.cpp \
-o submodules/cas-bacnet-stack/bin/libCASBACnetStack_x64_Release.so
dotnet build -c Release # copies it next to the executableEither way, dotnet build copies the library from submodules/cas-bacnet-stack/bin/
into the same directory as BACnetProfileExampleBSSCS.dll/.exe
(bin/Release/net8.0/, gitignored) - the .NET native-library resolver looks
there first.
The stack's C# adapter selects the native library filename with #if DEBUG /
#else: CASBACnetStack_x64_Debug in a Debug build,
CASBACnetStack_x64_Release in Release. The stack's MSVC solution only has a
ReleaseDll configuration (see above) - there is no matching DebugDll that
would produce CASBACnetStack_x64_Debug.dll. So build and run this example in
Release; a Debug build starts but fails to load the native library the
first time it calls into the stack (see
Troubleshooting) unless you first add a
DebugDll configuration to the stack's solution yourself.
The .csproj includes all three of the adapter's files for parity with its
expected set (see submodules/cas-bacnet-stack/adapters/csharp/selftest/PropertyBufferHelperSelfTest.csproj
for the precedent), but PropertyBufferHelper.cs packs buffer-shaped Send*
calls (ReadProperty/WriteProperty/CreateObject as a client) that this
read-only B-SS example never makes - a Smart Sensor only ever answers
ReadProperty, it never initiates one. It compiles in unused; that is a
documented, deliberate choice, not an oversight.
dotnet run -c Release -- --port 47821 --deviceID 12345
# or, after `dotnet build -c Release`, run the built executable directly:
./bin/Release/net8.0/BACnetProfileExampleBSSCS --port 47821Expected output:
BACnet B-SS (Smart Sensor) Example - C# v1.1.0
CAS BACnet Stack version: 6.0.23.0
Common helper (common/) version: 1.1.0
FYI: listening on <your-ip>:47808 (broadcast <your-subnet-broadcast>)
FYI: Device 389001 ("Chipkin Example B-SS") ready. Vendor ID 389. Press 'h' for help.
The device listens on UDP 47808 (BACnet/IP) by default. Allow that port
through your firewall. To use a different port, pass --port.
| Option | Default | Meaning |
|---|---|---|
--port <n> |
47808 |
UDP port to listen on (BACnet/IP). |
--deviceID <n> |
389001 |
The device's BACnet instance number (BACnet requires this to be configurable). |
--help, -h |
- | Show usage and exit. |
--version |
- | Print the example and stack versions, then exit. |
While the example runs in a real console (not redirected - see TUTORIAL.md for what that means), these keys are available:
| Key | Action |
|---|---|
h |
Show the version information and this command list. |
q |
Quit. |
| up arrow | Nudge the simulated Analog Input 1 (Bronze) reading up by 1.1. |
| down arrow | Nudge the simulated Analog Input 1 (Bronze) reading down by 1.1. |
The up/down keys move the simulated temperature; the Simulation carries on
ramping from the new value, and a client re-reading it sees the change. Ctrl+C
also shuts the device down cleanly. With stdin redirected (a pipe, as the Wire
Tests run it) the arrows do not exist, but a q written to stdin still quits.
Use a BACnet client such as the CAS BACnet Explorer:
- Discover - send a Who-Is. The device replies with I-Am from instance 389001 (vendor 389). It also broadcasts an I-Am at start-up.
- Browse the object model - the device shows five objects: the Device
(
Chipkin Example B-SS), the three sensors, and the Network Port (Vermilion). Reading the Device'sObject_Listreturns all five. - Read the Device - ReadProperty
389001->Object_Namereturns"Chipkin Example B-SS";Protocol_Revisionreturns30;Descriptionreturns the profile description string. - Read a sensor - ReadProperty Analog Input
1->Present_Valuereturns the current simulated temperature (21.5at start-up, then 0.5 higher each second); read it again and it has moved.Unitsreturnsdegrees-Celsius;Reliabilityreturnsno-fault-detected;Status_Flagsreturns all FALSE;Out_Of_Servicereturnsfalse;Object_Namereturns"Bronze". Repeat for Binary Input1("Emerald", hasPolarity) and Multi-State Input1("Hot Pink", hasNumber_Of_States= 3). Every required property of every object is readable. - Confirm the profile boundary - a WriteProperty to any object is rejected. That is correct: a B-SS Smart Sensor is read-only.
For a property-by-property review against the conformance statement, see TUTORIAL.md.
The checks above, automated: a Python BACnet client (the Peer) drives the running
example over BACnet/IP from outside it. Python 3 standard library only. The
scripts are the C++ edition's tests/, unchanged except for one addition in
tests/bss_setup.py: --exe may be a whole command line (split with shlex),
so the example can also be started as dotnet <dll>.
| Script | What it proves |
|---|---|
discovery_test.py |
Who-Is, the Device's Object_List, then for every object its Property_List and a ReadProperty of every property it lists - every read comes back as a value. |
sensing_test.py |
The Profile Function. Reads the three sensors again and again for 12 s; the readings follow the Simulation (0.5 C steps, a toggle every 3 s, states in order). Fails against a sensor that serves constants. |
failure_modes_test.py |
The Failure Modes. Breaks the simulated sensor wire: Reliability open-loop, Status_Flags FAULT, a frozen reading; repairs it: all clear, the reading moves. Then the errors for an unknown object / property / array index, and the Reject for a WriteProperty. |
Run them all (after dotnet build -c Release, with the native library in the
build output):
python tests/run_wire_tests.py # default --exe bin/Release/net8.0/BACnetProfileExampleBSSCS(.exe)
python tests/run_wire_tests.py --port 47821 --exe "dotnet bin/Release/net8.0/BACnetProfileExampleBSSCS.dll"It ends with ALL WIRE TESTS PASSED (exit 0); about 25 seconds.
tests/README.md says what each check proves. Verified on
Windows only (3 runs in a row, 36/36 checks each, no [RETRY] lines); the
port has not been run on Linux locally. CI (.github/workflows/release.yml) runs
them on Linux after the smoke test.
If you have read either sibling example, the object model and callback shapes
are identical - this section is only about what is mechanically different
because C# talks to the stack through P/Invoke instead of an embedded link or
an N-API addon. See common/CHANGELOG.md for the full list; the highlights:
- No
LoadBACnetFunctions(). The C# adapter'sBACnetStack_*methods are plain[DllImport] static externdeclarations; the .NET runtime resolves the native library the first time one is called, not up front.Program.cstreats that first call (insidePrintVersion()) as the load check. - Raw pointers, not managed buffers. Every
Get*Propertycallback takesbyte*/uint*/float*out-parameters matching the native C ABI directly - this project isunsafethroughout (<AllowUnsafeBlocks>true</AllowUnsafeBlocks>). - A separately built native library. There is no "compile the stack into
the executable" mode for C# (unlike the C++ edition's default SOURCE link
mode) and no addon build step baked into the package install (unlike Node's
npm install). You build the native shared library once, explicitly (see above), and it has to be found next to the executable at run time. - Delegates must be rooted in
static readonlyfields so the CLR cannot collect them while native code may still call back into their marshalling thunks - see the comments incommon/CASExampleHelper.csandProgram.cs.
The CAS BACnet Stack supports every standardized device profile in ASHRAE 135-2024 Annex L, and there is one example repository per profile. Pick the profile your device claims, then the language you build in. "Ask" means the example hasn't been built yet for that language - contact Chipkin if you need one.
| Profile | C++ | Node.js | C# | Rust | Python | Go |
|---|---|---|---|---|---|---|
| B-SS Smart Sensor | B-SS-CPP | B-SS-Node | B-SS-CS | B-SS-Rust | B-SS-Python | B-SS-Go |
| B-SA Smart Actuator | B-SA-CPP | Ask | Ask | Ask | Ask | Ask |
| B-ASC Application Specific Controller | B-ASC-CPP | B-ASC-Node | Ask | Ask | Ask | Ask |
| B-AAC Advanced Application Controller | B-AAC-CPP | Ask | Ask | Ask | Ask | Ask |
| B-BC Building Controller | B-BC-CPP | Ask | Ask | Ask | Ask | Ask |
| Profile | C++ | Node.js | C# | Rust | Python | Go |
|---|---|---|---|---|---|---|
| B-LSC Life Safety Controller | B-LSC-CPP π§ | Ask | Ask | Ask | Ask | Ask |
| B-ALSC Advanced Life Safety Controller | B-ALSC-CPP | Ask | Ask | Ask | Ask | Ask |
| Profile | C++ | Node.js | C# | Rust | Python | Go |
|---|---|---|---|---|---|---|
| B-ACC Access Control Controller | B-ACC-CPP | Ask | Ask | Ask | Ask | Ask |
| B-AACC Advanced Access Control Controller | B-AACC-CPP | Ask | Ask | Ask | Ask | Ask |
| Profile | C++ | Node.js | C# | Rust | Python | Go |
|---|---|---|---|---|---|---|
| B-LD Lighting Device | B-LD-CPP | Ask | Ask | Ask | Ask | Ask |
| B-LS Lighting Supervisor | B-LS-CPP | Ask | Ask | Ask | Ask | Ask |
| Profile | C++ | Node.js | C# | Rust | Python | Go |
|---|---|---|---|---|---|---|
| B-EM Elevator Monitor | B-EM-CPP | Ask | Ask | Ask | Ask | Ask |
| B-EC Elevator Controller | B-EC-CPP | Ask | Ask | Ask | Ask | Ask |
| B-AEC Advanced Elevator Controller | B-AEC-CPP | Ask | Ask | Ask | Ask | Ask |
| Profile | C++ | Node.js | C# | Rust | Python | Go |
|---|---|---|---|---|---|---|
| B-AS Authorization Server | B-AS-CPP | Ask | Ask | Ask | Ask | Ask |
| Profile | C++ | Node.js | C# | Rust | Python | Go |
|---|---|---|---|---|---|---|
| B-BBMD Broadcast Management Device | B-BBMD-CPP | Ask | Ask | Ask | Ask | Ask |
| B-ACDC Access Control Door Controller | B-ACDC-CPP | Ask | Ask | Ask | Ask | Ask |
| B-ACCR Access Control Credential Reader | B-ACCR-CPP | Ask | Ask | Ask | Ask | Ask |
| B-RTR Router | B-RTR-CPP | Ask | Ask | Ask | Ask | Ask |
| B-GW Gateway | B-GW-CPP | Ask | Ask | Ask | Ask | Ask |
| B-DAP Device Address Proxy | B-DAP-CPP | Ask | Ask | Ask | Ask | Ask |
| B-SCHUB BACnet/SC Hub | B-SCHUB-CPP | Ask | Ask | Ask | Ask | Ask |
| B-GENERAL General device (Annex L.8) | (satisfied by every example above) | β | β | β | β | β |
Client-side profiles.
| Profile | C++ | Node.js | C# | Rust | Python | Go |
|---|---|---|---|---|---|---|
| B-OD Operator Display | B-OD-CPP | Ask | Ask | Ask | Ask | Ask |
| B-OWS Operator Workstation | planned | β | β | β | β | β |
| B-AWS Advanced Operator Workstation | planned | β | β | β | β | β |
| B-XAWS Extended Advanced Operator Workstation | planned | β | β | β | β | β |
| B-LSAP Life Safety Annunciator Panel | planned | β | β | β | β | β |
| B-LSWS Life Safety Workstation | planned | β | β | β | β | β |
| B-ALSWS Advanced Life Safety Workstation | planned | β | β | β | β | β |
| B-ACSD Access Control Security Display | planned | β | β | β | β | β |
| B-ACWS Access Control Workstation | planned | β | β | β | β | β |
| B-AACWS Advanced Access Control Workstation | planned | β | β | β | β | β |
| B-LOD Lighting Operator Display | planned | β | β | β | β | β |
| B-ALWS Advanced Lighting Workstation | planned | β | β | β | β | β |
| B-LCS Lighting Control Station | planned | β | β | β | β | β |
| B-ALCS Advanced Lighting Control Station | planned | β | β | β | β | β |
| B-ED Elevator Display | planned | β | β | β | β | β |
| B-EWS Elevator Workstation | planned | β | β | β | β | β |
| B-AEWS Advanced Elevator Workstation | planned | β | β | β | β | β |
π§ = in progress. "Ask" = not yet built for that language; contact Chipkin if you need it. Profile definitions: ANSI/ASHRAE 135-2024 Annex L. BIBB definitions: Annex K. Get the stack: https://store.chipkin.com/services/stacks/bacnet-stack.
- ANSI/ASHRAE Standard 135 (BACnet) - the protocol standard. Object model (Clause 12), services (Clause 15), BACnet/IP (Annex J), device profiles (Annex L). Purchase / preview via the ASHRAE store.
- What is BACnet? - Chipkin's introduction: https://docs.chipkin.com/protocols/bacnet/.
- CAS BACnet Stack - product page and documentation: https://store.chipkin.com/services/stacks/bacnet-stack.
- CAS BACnet Explorer - client for testing this device: https://store.chipkin.com/products/tools/cas-bacnet-explorer.
- Shared helper used by this example -
common/README.md.
See also TUTORIAL.md, docs/PICS.md, CHANGELOG.md, and AGENTS.md.