38 changes: 19 additions & 19 deletions content/reference_implementation/laboratory-interoperability.md
Original file line number Diff line number Diff line change
Expand Up @@ -469,7 +469,7 @@ indicators depend on it.

**What this reference implementation does.** A repeatable lab report stage holding **one event per incoming
result, updated in place**. A report re-issued as a correction or amendment updates that same event rather than adding
another, so the record shows the current answer; the status change is recorded in the event notes. The program shape
another, so the record shows the current answer; the status change is recorded in the event notes and in the tracker change log. The program shape
this sits in — and the request stage that links to it — is described
under [The DHIS2 program shape](#lab_interop_prereq_program_shape).

Expand All @@ -480,23 +480,23 @@ decision above is an answer this implementation gave; where a different answer a
it. The table below is the whole section at a glance, in the order to work through it — each piece links to the part of
the guide behind it, and is described underneath.

| Piece | Effort | What it touches | What changing it means |
|-----------------------------------------------------------------------------|----------|--------------------------------------------------------|------------------------------------------------------------------------------------------------|
| [The program design](#lab_interop_decision_data_model) | Medium | Metadata, configuration, the transformation | The stages change and everything pointing at them follows |
| [The matching key, if not a specimen ID](#lab_interop_decision_identifier) | High | Search, sync state, failure handling, a new review app | Three parts reworked and a confirmation step that does not exist here |
| [The metadata the integration points at](#lab_interop_prereq_program_shape) | Low | Configuration | Replacing the metadata identifiers with local ones |
| [The terminology adopted](#lab_interop_decision_terminology_choice) | Medium | The codes themselves, and the binding below | Agreeing a coding system and, where it is not free, licensing it |
| [The terminology binding](#lab_interop_decision_terminology) | Low | DHIS2 metadata | Editing attributes on data elements and options; no code |
| [What the laboratory system emits](#lab_interop_decision_standard) | Low–High | The source side only | An address change if it speaks the same guide; a translation component to build and run if not |
| [The transformation](#lab_interop_decision_layer) | Medium | The DHIS2 datastore | Editing a script, not rebuilding and redeploying |
| [How results are triggered](#lab_interop_decision_push_or_poll) | Medium | Infrastructure to operate | An interval if polling stays; an endpoint to stand up and secure if push replaces it |
| [Failure handling](#lab_interop_decision_failures) | High | New components and named owners | Building a failure handling and alert mechanism |

**The program design.** Start here, because everything else points at it: which stages the case record has, whether a
| Piece | Effort | What it touches | What changing it means |
|------------------------------------------------------------------------------|----------|--------------------------------------------------------|------------------------------------------------------------------------------------------------|
| [Program design](#lab_interop_decision_data_model) | Medium | Metadata, configuration, the transformation | The stages change and everything pointing at them follows |
| [Matching attribute, if not a specimen ID](#lab_interop_decision_identifier) | High | Search, sync state, failure handling, a new review app | Three parts reworked and a confirmation step that does not exist here |
| [Metadata the integration points at](#lab_interop_prereq_program_shape) | Low | Configuration | Replacing the metadata identifiers with local ones |
| [Terminology adopted](#lab_interop_decision_terminology_choice) | Medium | The codes themselves, and the binding below | Agreeing a coding system and, where it is not free, licensing it |
| [Terminology binding](#lab_interop_decision_terminology) | Low | DHIS2 metadata | Editing attributes on data elements and options; no code |
| [What the laboratory system emits](#lab_interop_decision_standard) | Low–High | The source side only | An address change if it speaks the same guide; a translation component to build and run if not |
| [Data transformation](#lab_interop_decision_layer) | Medium | The DHIS2 datastore | Editing a script, not rebuilding and redeploying |
| [How results are triggered](#lab_interop_decision_push_or_poll) | Medium | Infrastructure to operate | An interval if polling stays; an endpoint to stand up and secure if push replaces it |
| [Failure handling](#lab_interop_decision_failures) | High | New components and named owners | Building a failure handling and alert mechanism |

**Program design.** Start here, because everything else points at it: which stages the case record has, whether a
case can carry more than one specimen and more than one result, and which result the indicators count. Matching on
something other than a specimen ID changes the shape of the request stage too.

**The matching key, if not a specimen ID.** Matching on something that identifies the person rather than the sample is
**Matching attribute, if not a specimen ID.** Matching on something that identifies the person rather than the sample is
not a setting to change. Three parts of the integration have to be rebuilt:

* **How the laboratory is searched.** Today it asks for one specimen ID and expects one report back. It would instead
Expand All @@ -507,24 +507,24 @@ not a setting to change. Three parts of the integration have to be rebuilt:
can a result that fits two cases — so somebody has to be shown the candidates and asked to choose, for example in a
custom app or plugin that does not exist yet, with the workload that comes with it.

**The metadata the integration points at.** It has to be told which program to work in, which stages hold the request
**Metadata the integration points at.** It has to be told which program to work in, which stages hold the request
and the report, which data element holds the identifier, and which attribute carries the laboratory codes. The
configuration key names are in
the [repository](https://github.com/dhis2/reference-dhis2-tracker-lab-result-integration).

**The terminology adopted.** Which coding system names the tests and the results — an international one, a national or
**Terminology adopted.** Which coding system names the tests and the results — an international one, a national or
local list, or both with the local list mapped across. Licensing can settle this, and it is a legal and procurement
question rather than a technical one, so establish where the country stands before any mapping work starts.

**The terminology binding.** The data elements and options have to carry the codes the laboratories actually report, so
**Terminology binding.** The data elements and options have to carry the codes the laboratories actually report, so
an arriving code can be looked up. Decide in advance what happens to a result whose code has no match, and give someone
the job of keeping the mapping current as codes and test panels change.

**What the laboratory system emits.** A stand-in server plays the laboratory here, producing exactly what the chosen
implementation guide describes. A real system that produces the same thing needs only an address change; one that
produces something else needs a translation step in between.

**The transformation.** The rules that turn an arriving report into a DHIS2 event live in DHIS2 itself, not inside the
**Data transformation.** The rules that turn an arriving report into a DHIS2 event live in DHIS2 itself, not inside the
integration's code. They have to match the local stages on one side and whatever the laboratory sends on the other.

**How results are triggered.** The integration asks the laboratory for new results on a schedule, which suits places
Expand Down
Loading