110 changes: 78 additions & 32 deletions broadlink/purifier.py
Original file line number Diff line number Diff line change
Expand Up @@ -25,8 +25,12 @@ class lifaair(Device):

TYPE = "LIFAAIR"

# Fan state byte values reported by the device. 0x01 means the main unit
# is offline / unpaired; temperature and humidity are then unavailable.
# Fan state byte (payload[55]). 0x01 is the purifier offline or unpaired.
# On this unit (fw 10026) that is flags 0xC0 and temperature/humidity
# bytes 00 00 00. Another LM05 instead kept raw 25 and 45 (decoded
# 2.5 deg C / 45 %) with no purifier paired (mjg59/python-broadlink#807);
# that is not special-cased. A restart or re-pair returns the purifier
# itself to AUTO.
FAN_STATE_TO_MODE = {
0x81: FanMode.OFF,
0xA5: FanMode.AUTO,
Expand Down Expand Up @@ -55,24 +59,39 @@ class _Action(enum.IntEnum):
}

def set_fan_mode(self, fan_mode: FanMode) -> dict:
"""Set mode of the fan. Returns updated state."""
if fan_mode == FanMode.MANUAL:
return self.set_fan_speed(50)

"""Set the fan mode. Returns the decoded response.

In OFF only OFF and AUTO are accepted; NIGHT, TURBO and
ANTI_ALLERGY raise the device error -5 (reported as StorageError)
and nothing changes. AUTO from OFF reports speed 30 and may drop
to 0 a few seconds later. NIGHT starts at 10, TURBO at 121,
ANTI_ALLERGY at 60. There is no MANUAL command; use set_fan_speed().
While the purifier main unit is offline the station rejects mode
commands with the device error -5 (StorageError); the mode is not
applied after the unit reconnects either.
"""
action_arg = self.FAN_MODE_TO_ACTION_ARG.get(fan_mode)
if action_arg is not None:
data = self._send(
self._Operation.SET_STATE, self._Action.SET_FAN_MODE, action_arg
)
return self._decode_state(data)

return self.get_state()
if action_arg is None:
raise ValueError(f"{fan_mode!r} has no mode command")
data = self._send(
self._Operation.SET_STATE, self._Action.SET_FAN_MODE, action_arg
)
return self._decode_state(data)

def set_fan_speed(self, fan_speed: int) -> dict:
"""Set fan speed (0-121). Returns updated state.

Note that fan mode will be changed to MANUAL by the device.
"""Set fan speed (0-121). Returns the decoded response.

Any mode except OFF reports MANUAL with the new speed (0 included).
In OFF the speed is applied and the fan spins, but the device keeps
reporting OFF. While the purifier main unit is offline the station
answers with success but returns the offline state (purifier_online
False) and the speed is not applied, neither then nor after the unit
reconnects.
"""
if not isinstance(fan_speed, int) or isinstance(fan_speed, bool):
raise ValueError("fan_speed must be an int in 0..121")
if not 0 <= fan_speed <= 121:
raise ValueError("fan_speed must be an int in 0..121")
data = self._send(
self._Operation.SET_STATE, self._Action.SET_FAN_SPEED, fan_speed
)
Expand All @@ -81,9 +100,14 @@ def set_fan_speed(self, fan_speed: int) -> dict:
def get_state(self) -> dict:
"""Return the current state of the purifier as a dict.

The smart remote contains CO2, TVOC, formaldehyde and PM sensors.
Temperature, humidity and fan state are fetched from the main unit,
which can be offline (unplugged or unpaired); those keys are then None.
CO2, TVOC, formaldehyde and PM come from the station. Temperature,
humidity, fan mode and fan speed come from the purifier. They are
None when it is offline (purifier_online is False); the speed byte
is then 0, a placeholder. Temperature and humidity are also None
when bytes 27-29 are placeholder zeros on the first poll after it
reconnects. Fan mode and fan speed are otherwise the values the
device reports, including AUTO at speed 0 and OFF with a non-zero
speed.

Format::

Expand All @@ -93,35 +117,54 @@ def get_state(self) -> dict:
"co2": 425, # int, ppm
"formaldehyde": 0.03, # float, mg/m3
"tvoc": 150, # int, ug/m3
"pm1": 5, # int, ug/m3 (PM1.0)
"pm2_5": 7, # int, ug/m3 (PM2.5)
"pm10": 9, # int, ug/m3 (PM10)
"fan_mode": FanMode.AUTO, # FanMode enum, or None
"fan_speed": 50, # int, 0-121
"pm1": 5, # int, ug/m3
"pm2_5": 7, # int, ug/m3
"pm10": 9, # int, ug/m3
"fan_mode": FanMode.AUTO, # FanMode, or None
"fan_speed": 50, # int 0-121, or None
"purifier_online": True, # bool, bit 7 of byte 55
}
"""
data = self._send(self._Operation.GET_STATE)
return self._decode_state(data)

def _decode_state(self, data: bytes) -> dict:
raw = self._decode_state_raw(data)
# Bit 7 of the fan-state byte is set whenever the purifier is online.
purifier_online = bool(raw["fan_state"] & 0x80)
fan_mode = self._decode_fan_mode(raw["fan_state"], raw["fan_flags"])
is_offline = fan_mode is None
# Bytes 27-29 are 00 00 00 when the purifier has no climate reading:
# it is offline, or this is the first poll after it reconnects
# (fan_state is already online). Not a real 0.0 deg C / 0 %.
if not purifier_online or (raw["temperature"] == 0 and raw["humidity"] == 0):
temperature = None
humidity = None
else:
temperature = raw["temperature"] / 10.0
humidity = raw["humidity"]
# Mode and speed are reported independently: AUTO can report speed 0
# (seen with clean air), and OFF reported speed 50 after set_fan_speed(50).
# Offline frames carry speed 0 as a placeholder.
return {
"temperature": None if is_offline else raw["temperature"] / 10.0,
"humidity": None if is_offline else raw["humidity"],
"temperature": temperature,
"humidity": humidity,
"co2": raw["co2"],
"formaldehyde": raw["formaldehyde"] / 100.0,
"tvoc": raw["tvoc"] * 10,
"pm1": raw["pm1"],
"pm2_5": raw["pm2_5"],
"pm10": raw["pm10"],
"fan_mode": fan_mode,
"fan_speed": raw["fan_speed"],
"fan_speed": raw["fan_speed"] if purifier_online else None,
"purifier_online": purifier_online,
}

def _decode_state_raw(self, data: bytes) -> dict:
# PM field order verified against LAM01/LM05 display (PM1 <= PM2.5 <= PM10).
# Byte 30 is always 0x02. Meaning unknown; not decoded.
# CO2 reads exactly 400 for up to ~10 s after the station starts (5/5)
# and was also seen once when the main unit dropped out. 400 ppm can
# be real, so it is kept.
return {
"temperature": data[27] + 256 * data[28],
"humidity": data[29],
Expand All @@ -137,13 +180,15 @@ def _decode_state_raw(self, data: bytes) -> dict:
}

def _decode_fan_mode(self, fan_state: int, fan_flags: int):
# Check offline before anti-allergy: unpaired units can clear bit 0x40
# while still reporting fan_state 0x01 and stale temp/humidity defaults.
if fan_state == 0x01:
# Bit 7 clear: purifier offline or unpaired (observed as 0x01, flags 0xC0).
if fan_state & 0x80 == 0:
return None
# Anti-allergy is 0x85 with bit 0x40 of the flags clear.
if fan_flags & 0x40 == 0:
return FanMode.ANTI_ALLERGY
return self.FAN_STATE_TO_MODE.get(fan_state, FanMode.UNKNOWN)
# Mode arguments 9 and 10 clear and set bit 0 of this byte without
# changing mode or speed; meaning unknown.
return self.FAN_STATE_TO_MODE.get(fan_state | 0x01, FanMode.UNKNOWN)

def _send(self, operation: int, action: int = 0, action_arg: int = 0) -> bytes:
"""Send a command to the device."""
Expand All @@ -166,5 +211,6 @@ def _send(self, operation: int, action: int = 0, action_arg: int = 0) -> bytes:
packet[0x01] = packet_len >> 8

resp = self.send_packet(0x6A, packet)
# Seen returning -5 sporadically during power-cycling and pairing; cause unknown.
e.check_error(resp[0x22:0x24])
return self.decrypt(resp[0x38:])
12 changes: 9 additions & 3 deletions cli/test_lifaair
Original file line number Diff line number Diff line change
Expand Up @@ -8,9 +8,10 @@ from broadlink import FanMode, lifaair
def print_state(state: dict):
temperature = state["temperature"]
humidity = state["humidity"]
fan_speed = state["fan_speed"]
print(
"-> Temperature=%s Humidity=%s CO2=%4dppm HCHO=%4.2fmg/m3 "
"TVOC=%4dug/m3 PM1=%2d PM2.5=%2d PM10=%2d FanSpeed=%d (%s)"
"TVOC=%4dug/m3 PM1=%2d PM2.5=%2d PM10=%2d FanSpeed=%s (%s) online=%s"
% (
"%2.1fC" % temperature if temperature is not None else "-----",
"%2d%%" % humidity if humidity is not None else "---",
Expand All @@ -20,8 +21,9 @@ def print_state(state: dict):
state["pm1"],
state["pm2_5"],
state["pm10"],
state["fan_speed"],
"%d" % fan_speed if fan_speed is not None else "---",
state["fan_mode"],
state["purifier_online"],
)
)

Expand All @@ -40,8 +42,12 @@ print(dev.get_fwversion())
print("Getting state...")
print_state(dev.get_state())

print(
"While OFF, modes other than OFF and AUTO are rejected with "
"error -5 and nothing changes."
)
for mode in FanMode:
if mode == FanMode.UNKNOWN:
if mode in (FanMode.MANUAL, FanMode.UNKNOWN):
continue
print("Setting fan mode to %s" % mode)
print_state(dev.set_fan_mode(mode))
Expand Down