Repository navigation
Conversation
This was referenced Oct 20, 2026
Owner
Author
|
Cleanup of verified stacked Git ancestry on 2026-10-22: original source SHA Closing this now as consolidated/superseded, NOT merged to main; no branch deletion, no source history loss, no ARSAS repin, no mainline engine source promotion. Original physical validation and follow-ups still apply, and #190 remains draft. If #190 is discarded, this PR is available to reopen. |
5 of 12 tasks
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Field control transactions take about 8–13 seconds, but existing evidence combines SBOw, Operate and asynchronous termination. This patch exposes local monotonic service and post-response wait durations in ordered wire-step details without changing checks, timeout or sequence semantics.
It also fixes an independently reproducible reporting defect: control InformationReports lacking the mandatory RptID/OptFlds header could enter the single-active-RCB fallback and inflate BRCB frame/missing-SqNum statistics. Such messages remain delivered to control subscribers and no longer enter persistent RCB projection.
Based on exact field engine ba21d88. Build: PASS, zero warnings/errors. Direct invocation of 64 relevant xUnit Fact tests: PASS; theory cases excluded from that count. Full runner/CI validation pending. All fixtures are synthetic project-owned data. Physical command latency improvement is NOT established; stage data is required to locate the remaining wait. No merge/release requested.